Flanged Connections, Flanges, Gaskets and Bolts

Created on 11.24

Flanged Connections, Flanges, Gaskets and Bolts

I. What Provides Sealing in a Flanged Connection?

A flange is a circular disc with a ring of bolt holes at the pipe end. One flange is welded to each pipe, a gasket is sandwiched face-to-face between them, and bolts and nuts are tightened around the bolt circle to form a detachable connection. Sealing does not rely on hard metal-to-metal contact; instead, the bolts compress a resilient gasket between the two flanges, and the gasket fills minute irregularities on the sealing faces to form a seal.
Common causes of flange leakage:
  • Flanges not parallel or not concentric;
  • Incorrect gasket selection or off-center gasket compression;
  • Uneven bolt torque or insufficient tightening;
  • Scratches on the sealing face.
Temperature and pressure fluctuations can also cause gasket relaxation. According to Clause 7.3.1 of GB 50235-2010, before flange installation the sealing face shall be inspected; it shall be flat and clean, and free from scratches, corrosion and other defects that may affect sealing performance.
Cutaway diagram of a bolted flanged pipe connection showing gasket compression between two flanges by bolts
Three mandatory requirements for mating flanges:
  • The two mating flanges on the same pipeline must have identical pressure rating, sealing face type and nominal diameter; PN 10 and PN 16 shall not be force-matched;
  • Flanges with through scratches on the sealing face or with deformation shall not be used;
  • Bolts shall be tightened diagonally in 2–3 passes to uniform torque; tightening from one side only will extrude the gasket.

II. Four Common Flange Types: Selection from Economical to Severe Service

Selection principle: the more severe the service, the more a weld-neck flange is required; for general low-pressure service, a plate flange is the most economical.
Fillet-welded plate flanges (PL) and slip-on flanges (SO) shall not be used on high-pressure lines requiring full non-destructive examination of welds.
Other types include:
  • Socket-weld flange (SW);
  • Threaded flange (TH): no welding required; not suitable above 260°C or below −45°C;
  • Lap-joint/loose flange (PJ): can save corrosion-resistant material in corrosive media;
  • Integral flange (IF), etc.
According to GB/T 9124.1-2019, PN-series flanges cover nominal pressures PN 2.5–PN 400 and nominal sizes DN 10–DN 4000. HG/T 20592-2009 covers type designations and dimensions for PL, SO, WN, BL, etc., with nine PN levels from PN 2.5 to PN 160.
Comparison chart of four flange types: plate flange PL, slip-on flange SO, weld-neck flange WN and blind flange BL in cross-section

III. Four Common Sealing Face Types: They Determine How the Gasket Is Placed

In addition, there is the male-and-female face (MFM), in which the gasket self-centers in the groove and is resistant to blow-out; its tightness requirement lies between that of the raised face (RF) and the tongue-and-groove face (TG).
The sealing face must be matched with the gasket:
  • RF shall not be used with an RJ metal ring gasket;
  • Flat face (FF) is generally used with a full-face gasket.
RF raised-face heights are commonly 1.6 mm and 6.4 mm. The serrations are intended to increase sealing specific pressure and bite into the gasket; they are not defects.
According to GB/T 9124.2-2019, Class-series flanges include FF, RF, TG, RJ and other sealing face types; the standard specifies types, dimensions and pressure-temperature ratings.
Flange sealing face types comparison: raised face RF, flat face FF, tongue-and-groove face TG and ring joint RJ with their matching gaskets

IV. How to Match Gaskets and Bolts

Select non-metallic gaskets according to temperature, pressure and medium:
  • Rubber, non-asbestos fiber, PTFE and flexible graphite;
  • Low cost and easy to compress;
  • Used for low-pressure ambient-temperature service or the corresponding temperature range;
  • PTFE is corrosion-resistant; graphite is high-temperature resistant.
Semi-metallic gaskets:
  • Represented by spiral-wound gaskets;
  • Metal strip and graphite or PTFE strip are wound alternately;
  • With inner and outer rings;
  • Good resilience and temperature/pressure resistance;
  • Commonly used for medium-pressure steam and oil service.
Metallic gaskets:
  • Metal ring gasket (octagonal or oval ring for RJ);
  • Serrated gasket;
  • Corrugated gasket;
  • Used for high-temperature and high-pressure service requiring high sealing specific pressure.
Bolts:
  • Strength grade, quantity and size shall follow the flange pressure rating;
  • Ensure the gasket is compressed to the specific pressure required for sealing;
  • At high temperatures, consider bolt relaxation and select suitable material.
Gaskets are not better the thicker they are: select the thinnest gasket that satisfies sealing; thick gaskets are prone to crushing and creep. Bolts in the same bolt circle shall be of the same material and specification; old and new bolts shall not be mixed. For spiral-wound gaskets, ensure the inner and outer rings are not compressed off-center. Metal ring gaskets and grooves shall be clean and free from scratches; anti-seize compound may be applied.
Bolt tightening: symmetrical, diagonal and in stages. According to Clause 7.3.4 of GB 50235-2010, flanged connections shall use bolts of the same specification and the same installation direction; bolts shall be tightened symmetrically and evenly with moderate tightness; after nut tightening, the exposed bolt length should preferably be uniform; over-tightening shall not be used to eliminate misalignment. Clause 7.3.5 specifies that bolt tightening torque shall comply with design documents and relevant standards.

V. PN and Class: Do Not Mix the Two Systems

European-system PN uses bar as the unit. PN 16 means 16 bar, approximately 1.6 MPa; on site it is colloquially called “16 kg”. American-system Class is expressed in pound classes (Class 150, 300, 600, 900, etc.). MPa ≈ 0.007 × LB; this is only approximate. 1 bar = 0.1 MPa.
Key reminder: flanges with different pressure ratings or different standard systems shall not be directly mated; bolt hole spacing and sealing dimensions may not match. Within the same project, use one standard system as far as possible. Actual pressure capability decreases as temperature increases; use the pressure-temperature rating tables in the standard.
According to GB/T 9124.1-2019 and GB/T 9124.2-2019, the PN series (European, bar) and Class series (American, LB) shall be selected separately and shall not be mixed.

VI. Installation Key Points

Before installation:
  • Verify that nominal diameter, pressure rating, standard system and sealing face type are all consistent;
  • Check that the sealing face is free from scratches;
  • Confirm that the gasket matches the medium temperature and pressure.
During assembly:
  • The two flanges shall be parallel and concentric;
  • The gasket shall be centered;
  • Do not use multiple gaskets or tapered gaskets/shims to make up clearance;
  • Tighten bolts diagonally in 2–3 passes to the specified torque;
  • For high-temperature pipelines, hot tightening or cold tightening shall be carried out as required; threads may be coated with anti-seize compound.
After commissioning:
  • Check for leakage;
  • The gasket may relax during heating and pressurization; re-tighten if necessary;
  • After disassembly, old gaskets should in principle be replaced; clean the mating surfaces thoroughly before reassembly.
According to Clause 7.3.3 of GB 50235-2010, the flanged connection shall be concentric with the pipe, and bolt holes shall be arranged straddling the centerline; the flanges shall remain parallel, with deviation not greater than 0.15% of the flange outside diameter and not greater than 2 mm; over-tightening shall not be used to eliminate misalignment. Clause 7.3.7 specifies that flange bolts on high- or low-temperature pipelines shall be hot-tightened or cold-tightened as specified during trial operation.

VII. Frequently Asked Questions

What exactly is PN 16 in “kg” and MPa?
PN 16 = 16 bar ≈ 1.6 MPa. The colloquial “16 kg” means approximately 16 kgf/cm², basically corresponding to 1.6 MPa (1 MPa ≈ 10 kgf).
How to choose among plate flange (PL), slip-on flange (SO) and weld-neck flange (WN)?
For general low-pressure water, air and gas piping, PL is the most economical; for better rigidity, use SO; for high-temperature/high-pressure, low-temperature, or severe service requiring weld NDE, use WN.
Can raised face (RF) and flat face (FF) be mated?
Not recommended; standards also should not permit this. Their gasket and sealing dimensions differ: one has a raised face and the other is fully flat; insufficient compression may cause leakage. Matching requires identical sealing face type.
What PN is Class 150 equivalent to? Can it be directly replaced?
The ambient-temperature rating of Class 150 is approximately 2.0 MPa (carbon steel). Numerically it appears close to PN 20, but bolt holes, sealing dimensions and temperature-pressure curves differ; it cannot be simply equated or mixed. Conversion is only for estimation; actual selection shall follow the same system.
If a flange leaks, is it enough to tighten the bolts?
First determine the cause: off-center gasket compression, wrong gasket selection, scratched sealing face, flange deformation, etc. These cannot be solved by increasing torque; blind tightening may crush the gasket or break bolts. Depressurize, identify the cause, and replace the gasket or flange if necessary.
Note: Use PL for low pressure and WN for severe service; the sealing face and gasket must be matched; tighten bolts diagonally and evenly; only flanges in the same PN or Class system can be mated.

List of Referenced Standards

  • GB/T 9124.1-2019
Steel Pipe Flanges — Part 1: PN Series
  • GB/T 9124.2-2019
Steel Pipe Flanges — Part 2: Class Series
  • HG/T 20592-2009
Steel Pipe Flanges, Gaskets and Fasteners (PN Series)
  • GB 50235-2010
ASME STANDARD
  • ASME B16.5
  • ASME B16.47
Code for Construction of Industrial Metallic Piping Engineering, Section 7.3
Standards may be updated or superseded; actual implementation shall be based on the latest valid versions and design documents.
Contact
Leave your information and we will contact you.
WhatsApp